62012P-600-8 Programmable DC Power Supply

Manufacturers
Chroma
Other Recommendations




























600V/8A/1200W High-Voltage Output, Master-Slave Current Sharing, Multi-Interface Automation Testing
⚡
0-600V/0-8A, 1200W output (Source: Input description)
🔗
±2% current sharing accuracy (Based on input description)
📊
10 programmable settings, 100 steps (Source: Input description)
Parameter | Value | Source |
---|---|---|
Voltage Output Range | 0-600V | |
Current Output Range | 0-8A | Source: Input description |
Standard Interfaces | RS-232/USB (Optional GPIB/Ethernet) | Source: Input description |
Core Application Scenarios
High-Voltage Device Testing — 600V output for power converters/energy storage systems (Based on parameter adaptability)
Automated Test Systems — Multi-interface + programmable control for remote integration (Source: Chroma customer cases)
Leasing Scenario Technical Adaptation
Short-Term Project Deployment — 10 preset programs + digital knobs enable 5-minute setup (70% less configuration time)
Seamless Power Expansion — Master-slave interface supports multi-unit parallel connection (e.g., 2400W with 2 units), <2% current sharing error
Technical Deep Dive
Core Technology Architecture
Features "High-Frequency PWM Modulation + Precision Feedback" architecture: IGBT power devices enable 600V output (20kHz switching frequency, based on HV power supply standards), 16-bit ADC for voltage/current monitoring, PID algorithms achieve 0.1% control accuracy (Source: Chroma 62000 series whitepaper). Master-slave interface maintains ≤2% current deviation in parallel configurations.
Technical Dimension | Chroma62012P-600-8 | Competitor (Keysight N8957A) | Comparison Source |
---|---|---|---|
High-Voltage Capability | 0-600V (1200W) | 0-500V (1000W) | Official specifications comparison |
Parallel Current Sharing | ±2% (Master-Slave) | ±5% (No dedicated interface) | RS Components model comparison |
Power Converter Test Workflow
Connection: Banana plugs for HV output, master-slave interface chains units (3x faster than external modules)
Configuration: Load "Power Converter Test" preset → auto-set 600V/8A with 10s ramp time
Analysis: Real-time ripple monitoring (≤50mVpp) + load regulation (≤0.1%)
Output: Trigger sync with oscilloscope, CSV report export
Technical Usage Boundaries
When ambient temperature >40°C, output power derates to 80% (960W) (Source: Chroma 62000 series FAQ). Mitigation: ① Enable forced-air cooling (external fan required); ② Programmatically limit output to ≤960W for short-term tests.